Australian Standards & Certification for AMH20K

Guidance for suppliers and partners to meet compliance for modular homes. Core framework is NCC 2022 with relevant AS/NZS standards. Performance targets include NatHERS 7*, bushfire where applicable (AS 3959), and mandatory schemes such as WaterMark/WELS. System certification via CodeMark may apply to modular elements.
NCC 2022
AS/NZS
NatHERS 7*
AS 3959
WaterMark
WELS
CodeMark
NATA
Standards

Core framework

NCC 2022

Building Code structure (Volumes 1–3) covering structural, fire, services and energy efficiency.

AS/NZS

Referenced technical standards for materials, testing and installation.

NatHERS 7*

Thermal performance target per climate zone.

CodeMark
Optional scheme for product/system certification to streamline approvals.
NATA

Accreditation for testing laboratories; ILAC recognition for some overseas labs.

* Nullam metus mauris, vehicula non lobortis non, rutrum et erat. Praesent convallis posuere porttitor.

Key standards by category

CategoryTypical standardsEvidence requiredResponsible
Structure (steel, concrete, panels)AS/NZS 1163, 4600, 1397 (steel); AS 3600, AS 1379 (concrete); AS/NZS 1170 (actions)NATA test reports, mill certs, QA/QC recordsSupplier + Aura QA
Glazing & WindowsAS/NZS 2208 (safety), AS 2047 (window/door), AS 1288 (glass)Type tests, product certificatesSupplier
Cladding/RoofingAS/NZS 1562, AS/NZS 4601, AS 4040 (wind)Testing to profiles, corrosion category dataSupplier
MEP – ElectricalAS/NZS 3000, 3008, 61439, 60598CoC, type tests, RCM/MEPSSupplier + Installer
MEP – PlumbingAS/NZS 3500 series; WaterMark where applicableWaterMark license, WELS star ratingsSupplier
EnergyAS/NZS 5033, 4777 (PV); 3823 (HVAC)Accredited lab reports, installer sign‑offSupplier + Installer
BushfireAS 3959 (BAL)Site BAL assessment, compliant product specsAura + Authority
Indoor airVOC/low‑tox certificatesVOC/FORMaldehyde test reportsSupplier
Standards

CodeMark pathway (for modular elements)

Define scope & performance requirements (NCC referenced clauses).
Map existing evidence → test plan at NATA labs.
Factory Production Control (FPC) & QA documentation.
Issue Technical Manual & stakeholder training.
Submit to JAS‑ANZ accredited Certification Body.

* Benefits: recognised certificate across jurisdictions, streamlined approvals for repetitive modular elements.

Standards

Energy & NatHERS 7*

Thermal performance modelling per climate zone to achieve 7‑star target.
Envelope measures: insulation R‑values, low‑e glazing, air‑tightness.
All‑electric goal: heat pumps, efficient lighting, optional solar PV.
Standards

Bushfire, Durability & Safety

AS 3959 Bushfire Attack Level (BAL) assessment for relevant sites.
Durability categories for metals (corrosion) and timber treatments.
Slip resistance (AS/NZS 4586), waterproofing (AS 3740), acoustic (NCC/ISO).

Compliance checklist (supplier pack)

ItemSupplierAuraNotes
Product data sheets (PDS)Specs, composition, dimensions
AS/NZS test reports (NATA)Or ILAC‑recognised lab
VOC/low‑tox evidencePaints, boards, adhesives
Certificates (WaterMark/WELS)If applicable
FPC/QA proceduresAudit readiness
CodeMark dossier (if scoped)System certification
Standards

Typical certification timeline

Week 0–2:

Gap assessment, scope & evidence map.

Week 3–8:

NATA testing (book labs), draft documentation.

Week 9–12:

Factory QA audit, final reports.

Week 13–16:

CodeMark submission (if scoped) & approvals.

Timelines vary by category and lab capacity; critical-path items will be prioritised per delivery schedule.
Standards

Frequently asked questions

Yes, if the lab is ILAC‑recognised and the test method aligns with AS/NZS. Some categories still require NATA testing in Australia.
No. CodeMark is for defined systems/elements where a certificate streamlines approvals. Individual materials usually rely on AS/NZS evidence.
Licensed installers/engineers in Australia sign off electrical/plumbing/structural works as required by the NCC and state regulations.
Contact Us for More Questions